diamondspark, flux-cored wire, nickel alloys

diamondspark 900 BC flux-cored wire

EN ISO classification18276-A T89 4 Mn2Ni1CrMo B M21 3 H5
AWS classificationA5.29 / SFA-5.29 E120T5-GM-H4
Shielding gasM21: Ar with 15 to 25 % CO2
ApprovalsCE
Price on request
Give us the diameter and the quantity, we will quote during working hours

Spawlab is the data controller. We will use your data only for replying to this price enquiry. See the privacy policy for details.

Authorised distributorvoestalpine Böhler Welding
Courier shippingfrom the warehouse in Krotoszyn
Data sheetcomposition, properties, specifications
Wire selectionhelp from a welding engineer
Manufacturer data sheet
Application

What diamondspark 900 BC flux-cored wire is used for

diamondspark 900 BC is a seamless high-strength flux-cored wire of the basic type, alloyed with nickel, chromium and molybdenum, with a yield strength above 890 MPa.

Typical parent materials are S690Q, S890Q, S690QL, S890QL, S960Q, S960QL and ASTM A 709. The seamless make limits moisture pickup by the core and keeps the hydrogen level in the weld low, and the wire works on mobile structures, machine frames, cranes and parts built for a lower own weight.

  • Classification EN ISO: 18276-A T89 4 Mn2Ni1CrMo B M21 3 H5
  • AWS classification: A5.29 / SFA-5.29 E120T5-GM-H4
  • Shielding gas: M21
  • Diameters: 1.2 / 1.6 mm
  • Approvals: CE

Do not exceed the permitted interpass temperature, an overheated heat affected zone loses its toughness. Keep the wire in a dry store and use an opened pack promptly, a basic core is sensitive to moisture. Hold a short arc, a long one breaks the shielding and raises the hydrogen content in the weld. Match the diameter to the thickness and the position, thinner wires are easier to control in constrained positions.

Manufacturer datasheet

Chemical composition and properties from the manufacturer datasheet

Datasheet PDF

Typical weld metal values from the voestalpine Böhler Welding data sheet, issue 01/2024. The minimum or the range guaranteed by the maker is given in brackets. The figures depend on the heat treatment condition and the shielding gas stated in the row and do not replace testing the joint to your own WPS.

Chemical composition, wt.-%
CSiMnCrNiMo
gas M210,060,401,400,402,200,40
Welding data and approvals
Polaritydirect current, electrode positive (DC+)
Shielding gas to EN ISO 14175M2
ApprovalsCE
Datasheet edition01/2024
Mechanical properties of the all-weld metal, typical values
Condition Yield strength Re, MPa Tensile strength Rm, MPa Elongation A, % Impact energy KV, J at -40 °C
u 960 (min. 890) 1 010 (range 940 to 1180) 19 (min. 15) 75 (min. 47)
  • u: untreated, as welded, shielding gas M21
Fits

For which materials and machines

Base materials
  • S690Q
  • S890Q
  • S690QL
  • S890QL
  • S960Q
  • S960QL
  • ASTM A 709
Process and machines

Flux-cored wire, works on any sound machine for this process: welders. Shielding gas: M21: Ar with 15 to 25 % CO2.

Used welders New welders Ask us to help you choose
Technical substitute

A substitute for this consumable

We will find a substitute with the same classification, diameter and shielding gas over the phone: +48 669 162 833.

From the same group

Other consumables for the same material

For comparison before you buy. A technical substitute is listed above.

All: Flux-cored wires