Böhler Welding, solid MIG/MAG wire, mild and low-alloy steels

Pipeshield X 70 solid MIG/MAG wire

EN ISO classification14341-A G 46 4 M21 4Si1 G 46 2C1 4Si1
AWS classificationA5.18 / SFA-5.18 ER70S-6
Shielding gasC1: 100 % CO2, M2: Ar with 5 to 25 % CO2
ApprovalsTÜV (19421), CE
Price on request
Give us the diameter and the quantity, we will quote during working hours

Spawlab is the data controller. We will use your data only for replying to this price enquiry. See the privacy policy for details.

Authorised distributorvoestalpine Böhler Welding
Courier shippingfrom the warehouse in Krotoszyn
Data sheetcomposition, properties, specifications
Wire selectionhelp from a welding engineer
Manufacturer data sheet
Application

What Pipeshield X 70 solid MIG/MAG wire is used for

Pipeshield X 70 is a solid wire for mild steel. It suits welding mild and low-alloy steels, fine-grained grades included, on steel structures, tanks, machine frames and workshop work.

Parent materials are API 5L, L245MB, L485MB, L245NB and L415NB. All welding positions are open to it, which helps on site, and the wire does well on root runs.

  • Classification EN ISO: 14341-A G 46 4 M21 4Si1 G 46 2C1 4Si1
  • AWS classification: A5.18 / SFA-5.18 ER70S-6
  • Shielding gas: M2, C1
  • Diameters: 1.0 / 1.02 / 1.2 mm
  • Approvals: TÜV (19421), CE

On thicker parts and in a cold workshop plan preheating to cut the risk of cold cracking. Match the drive rolls to the wire diameter and check the liner, wire slip shows up at once in an unstable arc. Watch the wire stick-out from the contact tip, too long a one lowers the arc voltage and worsens the fusion.

Manufacturer datasheet

Chemical composition and properties from the manufacturer datasheet

Datasheet PDF

Typical weld metal values from the voestalpine Böhler Welding data sheet, issue 10/2023. The minimum or the range guaranteed by the maker is given in brackets. The figures depend on the heat treatment condition and the shielding gas stated in the row and do not replace testing the joint to your own WPS.

Welding data and approvals
Polaritydirect current, electrode positive (DC+)
Shielding gas to EN ISO 14175C1
ApprovalsTÜV (19421), CE
Datasheet edition10/2023
Mechanical properties of the all-weld metal, typical values
Condition Yield strength Re, MPa Tensile strength Rm, MPa Elongation A, % Impact energy KV, J at -20 °C Impact energy KV, J at -40 °C
u1 485 (min. 460) 595 (min. 570) 25 (min. 18) 120 (min. 50) 60 (min. 47)
u2 530 (min. 480) 615 (min. 580) 24 (min. 18) 140 (min. 75) 115 (min. 47)
u3 650 715 22 170 145
  • u1: untreated, as welded, shielding gas 100 % CO2
  • u2: untreated, as welded, shielding gas Ar + 15, 25 % CO2
  • u3: untreated, as welded, shielding gas M21, field result, round tensile specimen, longitudinal
Fits

For which materials and machines

Base materials
  • API 5L
  • L245MB
  • L485MB
  • L245NB
  • L415NB
Process and machines

Solid MIG/MAG wire, works on any sound machine for this process: welders. Shielding gas: C1: 100 % CO2, M2: Ar with 5 to 25 % CO2.

Used welders New welders Ask us to help you choose
Technical substitute

Consumables with the same classification

Same material group, matching classification, a shared diameter and the same shielding gas. Confirm any substitute for your WPS in the documentation.

From the same group

Other consumables for the same material

For comparison before you buy. A technical substitute is listed above.

All: Solid MIG/MAG wires